TT$7,725.00
Add to cart
Forza 3000VA UPS Rack Mountable OnLine FDC-3011RUL
Forza 3000VA UPS Rack Mountable OnLine FDC-3011RUL
Forza 3000VA UPS Rack Mountable OnLine FDC-3011RUL
Forza 3000VA UPS Rack Mountable OnLine FDC-3011RUL
Forza 3000VA UPS Rack Mountable OnLine FDC-3011RUL

Forza 3000VA UPS Rack Mountable OnLine FDC-3011RUL

TT$7,725.00Incl. tax

MPN: FDC-3011RUL
Capacity: 3000VA/3000W
Topology: Online Double Conversion
Waveform: Pure sine wave
Voltage: 120V
Type of input: NEMA L5-30P
Type of output: 8 x NEMA 5-20R & 1 x NEMA L5-30R
Communication: USB / SNMP / RS-232
Visual indicator: LCD Read more..

  • Delivery

    1-2 Business Days
  • Delivery Options

    TT$25.00 or Free In-store Pickup
  • Payment Options

    LINX or Credit Card
  • Need Assistance

    WhatsApp - 306-2319

Product description

  • MPN: FDC-3011RUL
  • Capacity: 3000VA/3000W
  • Topology: 
    Online Double Conversion
  • Waveform: 
    Pure sine wave
  • Voltage: 
    120V
  • Type of input: 
    NEMA L5-30P
  • Type of output: 
    8 x NEMA 5-20R & 1 x NEMA L5-30R
  • Communication: 
    USB / SNMP / RS-232
  • Visual indicator: 
    LCD status screen
  • Management software: 
    Forza Tracker
  • Warranty: 
    2 years

The new Atlas online series provides true double-conversion technology and the highest level of protection suitable for critical equipment. This series combine an optimized level of performance with rich functionality, resulting in a highly efficient system that is easy to maintain and operate. Designed to prevent unexpected service interruptions due to overloads, internal fault conditions or during blackouts, the UPS ensures reliable and continuous operation through its internal battery pack and an optional external battery module. Ideal for high density power protection demands, the Atlas features a versatile rack/tower form factor to fit diverse environments. Despite its compact footprint, this UPS incorporates internal battery packs which can be accessed via the front panel for maintenance checks and replacement without removing the UPS from its mounting rack. The LCD display panel can be easily shifted by pressing buttons to suit the installation format, vertically when mounted on a stand or horizontally if installed in a rack. Besides, IT personnel can manage equipment well from learning remaining backup time information via LCD display.

Online double conversion topology Online double conversion topology
Online UPS with true double-conversion technology offer the highest level of protection suitable for mission critical equipment by isolating the connected loads from raw utility power. This system works by converting power from AC to DC and then back to AC thanks to its two stage inverter and rectifier design.
Battery backup Battery backup
Supplies battery-derived backup power during blackouts, preventing loss of critical information and minimizing equipment stress caused by a hard shutdown. Delivers reserved energy long enough for equipment to properly shut down.
Automatic voltage regulation (AVR) Automatic voltage regulation (AVR)
Provides clean and stable AC power by automatically increasing low voltages during brownouts and decreasing overvoltages when irregularities are present on the main utility line.
Automatic shut-off Automatic shut-off
Guard your equipment against potentially damaging power fluctuations and other irregularities in the electrical supply by shutting down the power when voltage levels become too low or too high.
Surge protection, overload protection, electric discharge and voltage protection Surge protection, overload protection, electric discharge and voltage protection
Diverts excess voltage away from connected equipment during power surges or power spikes without reducing battery power used to run primary critical equipment. Extends battery life by preventing system overloads and controlling charging currents.
MOV Technology MOV Technology
Metal Oxide Varistor (MOV) technology helps absorb and it redirects transient energy preventing stray electricity from reaching protected equipment.
Thermofuse protection Thermofuse protection
Instantly disconnects the power when internal temperatures become dangerously high.
Power filters Power filters
Reduces electromagnetic interference (EMI) and radio frequency interference (RFI) to block unwanted noise, providing clean and distortion-free electricity to all power outlets.
Intelligent battery management Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Battery self-test Battery self-test
Ensures early failure notifications of bad or old batteries for immediate replacement, preventing any unexpected and unforeseen backup power issues.
Active power factor correction Active power factor correction
Counteracts harmonic distortion by modifying the power factor of the UPS in order to maximize the use of the electrical power from the main utility line.
Audible alarm Audible alarm
Provides audible notification of changing utility power and UPS power conditions for when the UPS is installed in hard to reach places or not easily seen by the user.
Cold start function Cold start function
Reserves temporary battery power used to start up the UPS in battery mode when the utility power is out. Restores immediate emergency power to the load after installing new batteries.
Data line protection Data line protection
Built-in data line protection prevents power surges that travel through telephone or Ethernet lines from causing damage to sensitive electronics.
Status LCD Status LCD
Displays live status of the UPS with detailed information on battery and power conditions, alerting users to potential problems before they can affect equipment and cause costly downtime.
Communication ports Communication ports
USB port enables the automatic shutdown function, safely powering down connected computers so as to prevent important data loss. Remotely manage and monitor UPS operations with the included user-friendly dashboard interface.
Forza tracker management software Forza tracker management software
Allows control and monitoring of multiple UPS units through a network connection. The software also prevents data loss from power outages by safely shutting down the UPS units while allowing the immediate detection and correction of any operation issues with minimal or no delay.
UL certified UL certified
UL certified for electrical safety and compliance. Recognized by global laboratories.
Inverter and generator compatible Inverter and generator compatible
Engineered to properly work with frequency variations caused by emergency inverters and backup generators in areas with severe electrical fluctuations.
Ventilation system Ventilation system
Extraction fan helps remove excess heat from the inside housing, guaranteeing to keep components within acceptable operating temperatures.
Metal housing Metal housing
Heavy-duty, impact-resistant metal construction
ECO Mode ECO Mode
Environmentally friendly mode which reduces energy consumption and improves overall efficiency by minimizing the waste of energy.
High efficiency High efficiency
Power factor ratio designed to maximize the use of in line electric power by improving power distribution to the connected loads
Emergency power-off EPO Emergency power-off EPO
Instantly shuts down the UPS and any connected equipment in the event of an emergency without the use of software.
Optional battery bank Optional battery bank
Increase the overall runtime of the UPS system, allowing users to maximize their current requirements without the roadblock of having to discard and upgrade to a new product down the line.
Intelligent card slot Intelligent card slot
Used to add an optional SNMP communication card for real-time monitoring and alerts of the UPS across a network.
2-year warranty 2-year warranty
Forza Power Technologies offers a direct replacement program that exchanges a defective product from the original purchase date. See warranty terms for details.

Reviews

0 reviews

Specifications

Forza 3000VA UPS Rack Mountable OnLine FDC-3011RUL

0 reviews

Available in store

Online and in-store prices may differ
Last updated: Today at 15:28

Review Forza Forza 3000VA UPS Rack Mountable OnLine FDC-3011RUL

MPN: FDC-3011RUL
Capacity: 3000VA/3000W
Topology: Online Double Conversion
Waveform: Pure sine wa..

Subscribe to our newsletter

Subscribe

Create an account

Having an account with us will allow you to check out faster in the future, store multiple addresses, view and track your orders in your account, and more.

Register

Recently added

You have no items in your shopping cart

Total incl. tax:TT$0.00